FULL LIFECYCLE POWER ASSET MANAGEMENT

DG SET SERVICE & POWER SOLUTIONS

A DG set is a vital backup power asset. Infocus Power Care delivers structured preventive maintenance, AMC programs, breakdown support, genuine spares, and load testing across Trivandrum and all Kerala districts.

Looking for service in Thiruvananthapuram? Visit our dedicated Trivandrum Regional Service Hub (Pattom) page.
Trivandrum DG Service Hub
OUR SERVICES

Complete DG Set Service & Maintenance Programs

Explore our specialized services designed to guarantee standby readiness, regulatory compliance, and maximum operational uptime.

DG Set Service & Routine Maintenance
01

Comprehensive scheduled service and multi-point health checks for diesel generators.

DG Set Service & Routine Maintenance

Scheduled periodic servicing and complete diagnostic checks covering all mechanical, fluid, electrical, and control systems to ensure optimum diesel generator readiness.

Comprehensive 45-point mechanical and electrical inspection
Engine lube oil drainage, flushing, and OEM-spec oil replenishment
DG Set Preventive Maintenance
02

Proactive care that prevents costly breakdowns and extends engine life.

DG Set Preventive Maintenance

Proactive maintenance protocol designed to catch developing component wear, fluid degradation, and electrical abnormalities before they cause downtime.

Running-hour and calendar-based scheduled preventive maintenance
Lubrication system analysis, filter renewal, and sealing gasket checks
Annual Maintenance Contract (AMC)
03

Tailored yearly maintenance programs ensuring 365-day standby readiness.

Annual Maintenance Contract (AMC)

Planned annual maintenance support based on equipment duty cycles and operational requirements, with priority emergency response and scheduled visits.

Scheduled periodic preventive maintenance visits (Monthly/Quarterly)
Priority 24×7 emergency breakdown dispatch with guaranteed response SLAs
Breakdown Support & Emergency Assistance
04

Rapid-response emergency troubleshooting to restore power fast.

Breakdown Support & Emergency Assistance

Quick troubleshooting for operational problems, focusing on fault identification, root-cause resolution, and practical corrective assistance across Kerala.

24×7 emergency helpline for immediate technical telephone triage
Rapid field technician dispatch to your site in Trivandrum and across Kerala
Genuine Spares & Replacement Parts
05

Authentic, high-grade replacement components engineered for maximum reliability.

Genuine Spares & Replacement Parts

Authentic OEM spare parts, filters, electrical modules, and mechanical overhaul components for all major diesel generator brands.

OEM lube oil filters, primary/secondary fuel filters, and water separators
High-efficiency air filter elements and crankcase breathers
Installation & Commissioning
06

Precision site integration, vibration isolation, and turnkey readiness verification.

Installation & Commissioning

Turnkey support for generator installation, plinth alignment, exhaust ventilation, electrical interconnection, and trial commissioning.

Site readiness evaluation (plinth level, acoustic positioning, air circulation)
Anti-vibration mount (AVM) positioning and base frame alignment
Load Testing & Performance Check
07

Verifying true real-world power capacity and transient load response.

Load Testing & Performance Check

Performance checks and controlled load bank testing help verify that the DG set responds correctly under full operating load conditions.

Resistive load bank testing across stepped loads (25%, 50%, 75%, 100%, and 110% peak)
Transient voltage and frequency response analysis during sudden step loading
MULTI-BRAND EXPERTISE

Specialized Servicing for Leading DG Manufacturers

Our certified field engineers possess deep technical expertise across all leading industrial and commercial diesel generator brands.

Infocus Power Care Certified Engineers Servicing Cummins, KOEL, CAT, FG Wilson, Mahindra, and Kirloskar Generators
Certified Field Service Squad

Infocus Power Care Field Engineers in Action

Caterpillar (CAT) Diesel Generator Set Servicing by Infocus Power Care
Caterpillar (CAT)

Supported Capacity

15 kVA – 2000+ kVA

100% Genuine Spares
Heavy-Duty Industrial Power Generation

Caterpillar (CAT) DG Set Engineering Solutions

Specialized servicing, diagnostic fault troubleshooting, scheduled AMC, and OEM filter/fluid care for CAT diesel generators.

CAT Electronic & ECM Diagnostics
OEM Filters & Genuine Fluid Top-Up
Resistive Step Load Bank Testing
Emergency Breakdown Field Support
Caterpillar (CAT) Diesel Generator
15 kVA – 2000+ kVA

Caterpillar (CAT)

Heavy-Duty Industrial Power Generation

Specialized servicing, diagnostic fault troubleshooting, scheduled AMC, and OEM filter/fluid care for CAT diesel generators.

CAT Electronic & ECM Diagnostics
OEM Filters & Genuine Fluid Top-Up
Cummins Diesel Generator
15 kVA – 1500 kVA

Cummins

Prime & Standby Power Generators

Comprehensive preventive maintenance, fuel injector calibration, PT fuel system diagnostics, and authentic spares for Cummins DG sets.

PT Fuel System & Injector Care
Fleet Preventive Maintenance
Kirloskar / KOEL Diesel Generator
5 kVA – 1010 kVA

Kirloskar / KOEL

Green & Green+ Series Power Units

Authorized-grade servicing, annual maintenance contracts (AMC), valve adjustments, and genuine parts supply for Kirloskar Oil Engines.

KOEL Green Series Maintenance
Scheduled AMC & Health Audits
Mahindra Powerol Diesel Generator
5 kVA – 625 kVA

Mahindra Powerol

Fuel-Efficient Commercial Power Sets

Routine checkups, cooling system descaling, electrical control panel diagnostics, and complete installation/commissioning for Mahindra DG sets.

Radiator Descaling & Cooling Care
AMF & Control Panel Servicing
Kohler SDMO Diesel Generator
10 kVA – 1250 kVA

Kohler SDMO

High-Performance Silent Generators

Acoustic canopy maintenance, electronic governor testing, excitation checks, and periodic AMC for Kohler SDMO soundproof generators.

Soundproof Acoustic Canopy Care
Decibel & Vibration Isolation
FG Wilson Diesel Generator
10 kVA – 2200 kVA

FG Wilson

Global Standard Acoustic Power Sets

Digital control module diagnostics, full load bank testing, sensor calibrations, and critical component replacements for FG Wilson generators.

Digital Control Module Diagnostics
Step Load Bank Verification
Atlas Copco Diesel Generator
9 kVA – 1250 kVA

Atlas Copco

Silent & Portable Industrial Units

Field troubleshooting, electrical wiring inspection, anti-vibration mount replacement, and scheduled preventive care for Atlas Copco generators.

QAS / QES Series Support
Anti-Vibration Mount (AVM) Checks
SERVICE CHECK AREAS

Comprehensive Diagnostic & Inspection Protocol

Our technicians examine every vital mechanical, fluid, electrical, and control system during maintenance visits to ensure dependable operation.

Industrial Diesel Generator Engine Compartment and Sensor Cluster Inspection
Component Diagnostic View

Multi-Point Preventive Diagnostics

01

Engine & Lubrication Checklist

Active Focus

Service condition, oil/lubrication requirements and visible abnormalities.

Lube oil viscosity, level, and contamination check
Lube oil filter replacement and sealing gasket inspection
Crankcase breather cleaning and blow-by observation
Oil pressure gauge sensor verification and leak checks
01.

Engine & Lubrication

Service condition, oil/lubrication requirements and visible abnormalities.

02.

Fuel System

Filters, connections, fuel-related issues and general condition.

03.

Cooling System

Coolant condition, radiator area and visible leakage/condition checks.

04.

Electrical System

Battery, charging, control panel, wiring and protection-related checks.

05.

Generator System

Operational condition, output-related checks and general inspection.

06.

Exhaust & Mounting

Visible condition, connections and vibration/noise observations.

07.

Testing & Trial Run

Operational run, load testing and performance observations where applicable.

SERVICE WORKFLOW

Structured Engineering Protocol

A systematic, five-stage engineering process designed to evaluate, maintain, test, and protect your generator assets.

01

Understand

Understand the equipment and service requirement.

We review your DG set specifications, running history, site application, and specific operating challenges.

Stage 01 Protocol
02

Inspect

Inspect operating condition and identify visible issues.

A qualified engineer performs a comprehensive physical and diagnostic inspection across all key subsystems.

Stage 02 Protocol
03

Service

Perform required maintenance or corrective work.

We execute precise maintenance, replace designated filters/fluids, or carry out targeted fault rectification.

Stage 03 Protocol
04

Test

Check operational performance and readiness.

The generator is subjected to operational run testing, parameter logging, and readiness verification.

Stage 04 Protocol
05

Support

Provide continued service support when required.

You receive complete service documentation along with continued 24x7 technical availability.

Stage 05 Protocol
READY WHEN YOU NEED IT

LET'S KEEP YOUR POWER READY

Whether you require routine service, AMC support, genuine spares, installation assistance, breakdown response, or performance checking, Infocus Power Care is ready to support your DG set requirements.

100% Genuine OEM Spares
24×7 Emergency Support
Cochin & Trivandrum Hubs