FULL LIFECYCLE POWER ASSET MANAGEMENT

DG SET SERVICE & POWER SOLUTIONS

A DG set is an important backup power asset. Regular attention helps maintain reliability and can identify developing issues before they become major failures.

OUR SERVICES

Complete DG Set Service & Maintenance Programs

Explore our specialized services designed to guarantee standby readiness, regulatory compliance, and maximum operational uptime.

DG Set Service & Preventive Maintenance
01

Proactive care that prevents costly breakdowns and extends engine life.

DG Set Service & Preventive Maintenance

Scheduled servicing and inspection covering key engine and generator components. Preventive maintenance helps maintain stable performance and reduce unexpected stoppages.

Scheduled periodic servicing based on running hours & calendar intervals
Engine oil drainage, system flushing, and fresh lube oil top-up
Annual Maintenance Contract (AMC)
02

Tailored yearly maintenance programs ensuring 365-day standby readiness.

Annual Maintenance Contract (AMC)

Planned annual maintenance support based on the customer's equipment and operating needs.

Structured schedule of periodic preventive maintenance visits (Monthly/Quarterly)
Priority 24x7 emergency breakdown dispatch with guaranteed response timeframes
Breakdown Support & Emergency Assistance
03

Rapid-response emergency troubleshooting to restore power fast.

Breakdown Support & Emergency Assistance

Quick troubleshooting for operational problems, focusing on fault identification and practical corrective assistance.

24x7 emergency response desk for immediate technical triage
Rapid field technician dispatch to your site across Kerala
Genuine Spares & Replacement Parts
04

Authentic, high-grade replacement components engineered for maximum reliability.

Genuine Spares & Replacement Parts

Quality replacement parts for routine servicing and corrective maintenance requirements.

Heavy-duty OEM-grade oil filters, fuel filters, and water separator elements
High-efficiency air filter elements and crankcase breathers
Installation & Commissioning
05

Precision site integration, vibration isolation, and turnkey readiness verification.

Installation & Commissioning

Support for installation, system checks, commissioning and readiness verification.

Site readiness evaluation (plinth design, ventilation airflow, acoustic compliance)
Vibration isolator (AVM mounts) positioning and base frame leveling
Load Testing & Performance Check
06

Verifying true real-world power capacity and transient load response.

Load Testing & Performance Check

Performance checks and load testing help verify that the DG set responds correctly under operating conditions.

Resistive load bank testing across stepped loads (25%, 50%, 75%, 100%, and 110% peak)
Transient response analysis during sudden step-load applications
MULTI-BRAND EXPERTISE

Specialized Servicing for Leading DG Manufacturers

Our certified field engineers possess deep technical expertise across all leading industrial and commercial diesel generator brands.

Infocus Power Care Certified Engineers Servicing Cummins, KOEL, CAT, FG Wilson, Mahindra, and Kirloskar Generators
Certified Field Service Squad

Infocus Power Care Field Engineers in Action

Caterpillar (CAT) Diesel Generator Set Servicing by Infocus Power Care
Caterpillar (CAT)

Supported Capacity

15 kVA – 2000+ kVA

100% Genuine Spares
Heavy-Duty Industrial Power Generation

Caterpillar (CAT) DG Set Engineering Solutions

Specialized servicing, diagnostic fault troubleshooting, scheduled AMC, and OEM filter/fluid care for CAT diesel generators.

CAT Electronic & ECM Diagnostics
OEM Filters & Genuine Fluid Top-Up
Resistive Step Load Bank Testing
Emergency Breakdown Field Support
Caterpillar (CAT) Diesel Generator
15 kVA – 2000+ kVA

Caterpillar (CAT)

Heavy-Duty Industrial Power Generation

Specialized servicing, diagnostic fault troubleshooting, scheduled AMC, and OEM filter/fluid care for CAT diesel generators.

CAT Electronic & ECM Diagnostics
OEM Filters & Genuine Fluid Top-Up
Cummins Diesel Generator
15 kVA – 1500 kVA

Cummins

Prime & Standby Power Generators

Comprehensive preventive maintenance, fuel injector calibration, PT fuel system diagnostics, and authentic spares for Cummins DG sets.

PT Fuel System & Injector Care
Fleet Preventive Maintenance
Kirloskar / KOEL Diesel Generator
5 kVA – 1010 kVA

Kirloskar / KOEL

Green & Green+ Series Power Units

Authorized-grade servicing, annual maintenance contracts (AMC), valve adjustments, and genuine parts supply for Kirloskar Oil Engines.

KOEL Green Series Maintenance
Scheduled AMC & Health Audits
Mahindra Powerol Diesel Generator
5 kVA – 625 kVA

Mahindra Powerol

Fuel-Efficient Commercial Power Sets

Routine checkups, cooling system descaling, electrical control panel diagnostics, and complete installation/commissioning for Mahindra DG sets.

Radiator Descaling & Cooling Care
AMF & Control Panel Servicing
Kohler SDMO Diesel Generator
10 kVA – 1250 kVA

Kohler SDMO

High-Performance Silent Generators

Acoustic canopy maintenance, electronic governor testing, excitation checks, and periodic AMC for Kohler SDMO soundproof generators.

Soundproof Acoustic Canopy Care
Decibel & Vibration Isolation
FG Wilson Diesel Generator
10 kVA – 2200 kVA

FG Wilson

Global Standard Acoustic Power Sets

Digital control module diagnostics, full load bank testing, sensor calibrations, and critical component replacements for FG Wilson generators.

Digital Control Module Diagnostics
Step Load Bank Verification
Atlas Copco Diesel Generator
9 kVA – 1250 kVA

Atlas Copco

Silent & Portable Industrial Units

Field troubleshooting, electrical wiring inspection, anti-vibration mount replacement, and scheduled preventive care for Atlas Copco generators.

QAS / QES Series Support
Anti-Vibration Mount (AVM) Checks
SERVICE CHECK AREAS

Comprehensive Diagnostic & Inspection Protocol

Our technicians examine every vital mechanical, fluid, electrical, and control system during maintenance visits to ensure dependable operation.

Industrial Diesel Generator Engine Compartment and Sensor Cluster Inspection
Component Diagnostic View

Multi-Point Preventive Diagnostics

01

Engine & Lubrication Checklist

Active Focus

Service condition, oil/lubrication requirements and visible abnormalities.

Lube oil viscosity, level, and contamination check
Lube oil filter replacement and sealing gasket inspection
Crankcase breather cleaning and blow-by observation
Oil pressure gauge sensor verification and leak checks
01.

Engine & Lubrication

Service condition, oil/lubrication requirements and visible abnormalities.

02.

Fuel System

Filters, connections, fuel-related issues and general condition.

03.

Cooling System

Coolant condition, radiator area and visible leakage/condition checks.

04.

Electrical System

Battery, charging, control panel, wiring and protection-related checks.

05.

Generator System

Operational condition, output-related checks and general inspection.

06.

Exhaust & Mounting

Visible condition, connections and vibration/noise observations.

07.

Testing & Trial Run

Operational run, load testing and performance observations where applicable.

SERVICE WORKFLOW

Structured Engineering Protocol

A systematic, five-stage engineering process designed to evaluate, maintain, test, and protect your generator assets.

01

Understand

Understand the equipment and service requirement.

We review your DG set specifications, running history, site application, and specific operating challenges.

Stage 01 Protocol
02

Inspect

Inspect operating condition and identify visible issues.

A qualified engineer performs a comprehensive physical and diagnostic inspection across all key subsystems.

Stage 02 Protocol
03

Service

Perform required maintenance or corrective work.

We execute precise maintenance, replace designated filters/fluids, or carry out targeted fault rectification.

Stage 03 Protocol
04

Test

Check operational performance and readiness.

The generator is subjected to operational run testing, parameter logging, and readiness verification.

Stage 04 Protocol
05

Support

Provide continued service support when required.

You receive complete service documentation along with continued 24x7 technical availability.

Stage 05 Protocol
READY WHEN YOU NEED IT

LET'S KEEP YOUR POWER READY

Whether you require routine service, AMC support, genuine spares, installation assistance, breakdown response, or performance checking, Infocus Power Care is ready to support your DG set requirements.

100% Genuine OEM Spares
24×7 Emergency Support
Cochin & Trivandrum Hubs